描述相符:
5.05.0分
服务态度:
5.05.0分
发货速度:
4.94.9分
商家店主:
创店时间:
2016-03-14
商品数量:
3169
所在地区:
上海市 嘉定区 江桥镇

金牌商家

AB 20BC2P1A0AYNANA0 变频器

  • 售价 联系客服 获取价格

    联系平台官方客服,更快,更优,有保障!

  • 会员价
  • 货期

    7天

  • 配送

    上海市闵行区 至 卖家承担运费

数量
- + (库存 100 台 )

金牌商家


我的认证 您的信赖

上海甲克自动化科技有限公司

好评率:100%

动态评价

描述相符:5.05.0分

服务态度:5.05.0分

发货速度:4.94.9分

物流速度:4.94.9分

店铺信息

认证信息: 已认证

保证金:10000.00

商品数量:3169

创店时间:2016-03-14

  • 品牌:AB

变频器

Technical Specifications

Mechanical

Degree of protection (IP)IP20
Shock15 G peak for 11 ms duration (±1.0 ms)
PWM frequency4 kHz @ 540V DC
Vibration0.152 mm (0.006 inch) displacement, 1 G peak

Electrical

Number of analogue outputs2
Mains voltage400 V
Integrated breaking resistanceNo
Brake IGBTBrake IGBT installed
Internal communication moduleNo communication module
Fuse current rating6 A @ 540V DC
Input voltage rating400V AC, 3-phase, 50 Hz
AC input undervoltage trip233V AC @ 380/400V
Bus voltage, nom540V DC @ 380/400V
Bus undervoltage shutoff/fault305V DC @ 380/400V
Bus overvoltage trip810V DC @ 380/400V
Output voltage rating0...400V AC @ 380...400V AC, 1-phase
Circuit breaker current rating, max15 A @ 400V AC, 3-phase
Motor circuit protector current rating, max3 A @ 400V AC, 3-phase
Output current rating, continuous2.1 A @ 540V DC
Output current rating, 1 min2.4 A @ 540V DC
Output current rating, 3 sec3.2 A @ 540V DC
Logic control ride-thru0.5 seconds minimum, 2 seconds typical
Brake resistorNo internal brake resistor
Input current rating2.1 A @ 540V DC
DocumentationManual
Carrier frequency2, 4, 8, and 10 kHz. Drive rating based on 4 kHz
Encoder quadrature90 degrees, ±27 degrees at 25 °C (77 °F)
AC input overvoltage trip570V AC @ 380/400V
Input power rating1.3 kVA @ 400V AC, 3-phase
Dual element time delay fuse current rating3...6 A @ 400V AC, 3-phase
Non-time delay fuse current rating3...8 A @ 400V AC, 3-phase
Digital input latency, typical9.2 ms @ stop signal for SVC motor control
Heat sink thermistorMonitored by microprocessor overtemp trip
Digital input latency9.2...16.0 ms @ start signal for SVC motor control
Drive to motor power ratio, maxRecommended not greater than 2:1 ratio
Stop modesMultiple programmable stop modes including — Ramp, Coast, DC-brake, Fast brake, Ramp-to-hold and S-curve
Frequency accuracyDigital input: within ±0.01% of set output frequency
Acceleration/decelerationTwo independently programmable accel and decel times. Each time can be programmed from 0...3600 seconds in 0.1 second increments
Analog input latency, typical6.4 ms @ speed signal for SVC motor control
Number of digital inputs6
Number of digital outputs3
Number of analogue inputs2
Internal watts loss44 W @ 400V, 0.75 Hp normal duty (IP20, NEMA/UL Type 1)
Motor voltage, nom400V @ 380...480V drive rating, 400V nominal line voltage
Supporting protocol for DeviceNetYes
Human interface modelNo HIM (blank plate inserted)
Max. output frequency400 Hz
External watts loss19 W @ 400V, 0.75 Hp normal duty (IP20, NEMA/UL Type 1)
Total watts loss63 W @ 400V, 0.75 Hp normal duty (IP20, NEMA/UL Type 1)
Supporting protocol for EtherNet/IPYes
Line voltage, nom400V @ 380...480V drive rating, 400V nominal motor voltage
Mains frequency50 Hz
Output frequency rangeStandard control: 0...400 Hz, vector control: 0...420 Hz
Actual short circuit ratingDetermined by AIC rating of installed fuse/circuit breaker
Internal EMC filteringWith EMC filter with common mode choke
Custom drive/firmwareNo custom firmware
Feedback optionNo feedback
Analog input latency4.8...12.4 ms @ speed signal for SVC motor control
Drive full power range400...528V @ 380...480V drive rating
Drive operating range342...528V @ 380...480V drive rating
Torque regulationWithout feedback: ±5 %, 600 rad/sec bandwidth
Enclosure typeIP20/NEMA/UL Type 1
Output current rating2.1 amps, 0.75 kW normal duty, 0.55 kW heavy duty, frame 0
Control optionsStandard control with 24V AC/DC I/O
Drive overcurrent tripInstantaneous current limit: 220...300% of rated current (dependent on drive rating)
Efficiency97.5% at rated amps, nominal line volts
Encoder supply12V, 250 mA. 12V, 10 mA minimum inputs isolated with differential transmitter, 250 kHz maximum
Speed control-speed regulationWithout feedback (Vector Control Mode): 0.1 % of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Current limit capabilityProactive current limit programmable from 20...160% of rated output current, Independently programmable proportional and integral gain
Selectable motor controlSensorless vector with full tuning. Standards V/Hz with full custom capability and vector control
Frequency control-speed regulationWith slip compensation (Volts per Hertz mode): 0.5% of base speed across 40:1 speed range, 40:1 operating range, 10 rad/sec bandwidth
Input phases3-phase input provides full rating for all drives. 1-phase operation possible on certain drives and provides 50 % of rated current. Frames 0...6: drive can be supplied as 6 pulse or 18 pulse in an engineered package.
Control methodSine coded PWM with programmable carrier frequency, ratings apply to all drives, the drive can be supplied as 6 pulse or 18 pulse in an engineered solution
Encoder requirementsEncoders must be line driver type, quadrature (dual channel) or pulse (single channel), 8...15V DC output (4...6V DC when jumpers are in 5V position), single-ended or differential and capable of supplying a min. of 10 mA per channel, maximum input frequen
Number of phases output3
Number of phases input3
Relative symmetric net voltage tolerance10 %
With control elementYes
Supporting protocol for LONYes
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Motor overload protectionFrames 0...6 standard control: powerflex 700 drives with standard control, which is identified by an N, A, or B in position 15 of the catalog number, only provide Class 10 motor overload protection according to NEC article 430, they do not provide speed
Input frequency tolerance47 Hz
Encoder duty cycle50% ±10%
Displacement power factor (all drives)0.98 across speed range
Short circuit rating, max200000 amps symmetrical
Output voltage range0 to rated motor voltage
Encoder typeIncremental, dual channel
Power ride-thru15 milliseconds at full load
Short circuit tripPhase-to-phase on drive output
Ground fault tripPhase-to-ground on drive output
Drive to motor power ratio, minRecommended not less than 1:2 ratio
Control logic noise immunityShowering arc transients upto 1500V peak
Line transientsUp to 6000 volts peak per IEEE C62.41-1991
Intermittent overload110% overload capability for up to 1 minute, 150% overload capability for up to 3 seconds

Construction

Height, approxIP20, NEMA/UL type 1: 336 mm
Depth, approxIP20, NEMA/UL type 1: 200 mm
Width, approxIP20, NEMA/UL type 1: 110 mm
Weight, approxIP20, NEMA/UL type 1: 8.16 kg (drive and packaging weight)

Environmental

Sound levelFrame 0: 58 dB @ 30 CFM fan velocity
Altitude1000 m (3300 ft.) maximum without derating
Degree of protection (NEMA)1
Surrounding air temperatureIP20, NEMA/UL type 1 (with top label): 0...50 °C (0...122 °F) @ frames 5…6, most ratings
AtmosphereDrive must not be installed in an area where the ambient atmosphere contains volatile or corrosive gas, vapors or dust, If the drive is not going to be installed immediately, store the drive where it is not exposed to a corrosive atmosphere
Operating temperature50 °C @ 540V DC
Storage temperature-40 °C
Relative humidity5...95% noncondensing
Pollution degree 1 according to EN 61800-5-1No pollution occurs, only dry non-conductive pollution occurs, and has no influence
Pollution degree 4 according to EN 61800-5-1The pollution generates persistent conductivity caused, for example, by conductive dust, rain or snow
Pollution degree 3 according to EN 61800-5-1Conductive pollution occurs, dry non-conductive pollution occurs and becomes conductive due to condensation
Pollution degree 2 according to EN 61800-5-1Normally only non-conductive pollution occurs, Occasionally a temporary conductivity, caused by condensation is expected when the drive is out of operation
Surrounding environment pollution degreeAll enclosures are acceptable for pollution degree 1 and 2, an enclosure that meets or exceeds IP54, NEMA/UL Type 12, is required for pollution degree 3 and 4


Top